ABB Medium-Voltage Circuit Breakers: VD4 & HD4
Compare vacuum and SF₆ breaker families for the specified interruption duty.
Explore the rangeOverview
Compare VD4 vacuum circuit breakers with HD4 SF₆ circuit breakers. For a new installation or a replacement, match the electrical ratings, mounting arrangement and switchgear interfaces to the exact breaker model.
VD4 vacuum circuit breakers
VD4 is an indoor breaker for primary distribution. A stored-energy spring mechanism operates contacts inside sealed vacuum interrupters. ABB offers both fixed and withdrawable versions for different switchgear arrangements.
In an incoming or outgoing feeder panel, the breaker carries normal load current and interrupts fault current on a relay trip. For a withdrawable unit, match the truck and primary contacts as well as the continuous-current and breaking ratings.

VD4 evo monitoring and diagnostics
VD4 evo adds sensor options to the VD4 vacuum breaker for monitoring temperature, mechanical operation and electrical condition. ABB also offers versions supplied without sensors that can be upgraded later.
At a site maintaining several breakers, remotely available condition data can help the maintenance team identify which unit needs inspection. Confirm which measurements and remote connections are included in the selected configuration.

iVD4 intelligent vacuum circuit breakers
The iVD4 solution combines a VD4 vacuum breaker with sensors and monitoring units. It can track contact temperature, the operating mechanism, auxiliary circuits and the motorized truck so that changes in the breaker’s condition are visible.
For an industrial feeder where an unplanned outage disrupts production, maintenance staff can review a thermal warning alongside mechanism and truck diagnostics to plan the next inspection.
ABB iVD4 monitoring and diagnostics (Chinese)
HD4 SF₆ circuit breakers
HD4 uses SF₆ gas in its poles for insulation and arc interruption, with a spring-operated mechanism. Fixed and withdrawable versions exist, and some configurations include gas-pressure monitoring.
For an installed HD4/UniAir breaker, ABB’s service programme covers spare parts and replacement options. Use the original nameplate and switchgear drawings to establish which service or retrofit applies to that bay.
ABB service for HD4/UniAir breakers
What to bring to a selection review
Provide rated voltage and current, required short-circuit breaking capacity, fixed or withdrawable mounting and pole spacing. Include the original nameplate, switchgear drawings, control supply and interlocking details when assessing a replacement.
Selection and replacement
Provide voltage, current, short-circuit interruption requirements, fixed or withdrawable arrangement, pole spacing and existing switchgear information. Similar appearance or naming does not establish interchangeability. Mechanical interlocks, control supplies and electrical interfaces require verification.
Discuss the installation with Forte
For a Taiwan project, include the installation location, required delivery window and any existing panel information. Forte can review the enquiry and confirm the applicable models and scope for the project.
Discuss your project with Forte
Send your single-line diagram, model reference or project requirements.
Discuss breaker selection or replacement