ABB Current and Voltage Transformers (CT/VT)
Provide secondary current and voltage signals for metering and protection.
Explore the rangeOverview
Current transformers (CTs) and voltage transformers (VTs, also called PTs) provide secondary signals for metering and protection. Start with the measured quantity, ratio, burden, accuracy class and space available in the panel.
TPU indoor current transformers
TPU combines current measurement with busbar support in an epoxy-cast body. Different core arrangements serve metering and protection; selected versions offer reconnectable ratios or a capacitive divider for voltage indication.
For indoor switchgear, compact substations, motor and generator circuits, capacitor banks and dry-type transformers.

KOKS indoor current transformers
KOKS is an epoxy-cast bus-type current transformer with medium-voltage insulation but no integral primary conductor. The switchgear busbar passes through the transformer, allowing measurement around the existing current path.
For higher-current primary air-insulated switchgear and current measurement in motor or generator installations.

TJC voltage transformers
TJC is an epoxy-cast, single-pole voltage transformer supplied without a primary fuse. One end of its primary winding is earthed; secondary windings provide voltage signals for metering and protection.
For voltage measurement in indoor switchgear, compact substations, motor and generator circuits, and capacitor banks.

TJP voltage transformers with fuse options
TJP combines single-pole voltage measurement with primary-fuse options. Its fuse-holder arrangements accommodate fixed installations or withdrawable VT trucks, with fuse indication options to suit the selected assembly.
For switchgear and compact substations requiring a fused voltage-measurement circuit, including accessible withdrawable VT assemblies.

TDC double-pole voltage transformers
TDC measures phase-to-phase voltage through a double-pole, epoxy-cast design. Both primary terminals and the primary winding are insulated from earth, distinguishing it from single-pole, phase-to-earth transformers.
For air-insulated switchgear, motors, generators, drives and capacitor banks; selected configurations can also supply external auxiliary power.

What to bring to a selection review
For each measurement or protection circuit, specify the primary and secondary values, accuracy class, burden and insulation level. Include the mounting dimensions, terminal arrangement, number of CT cores or VT windings, and the required fuse arrangement for a VT.
Confirm the model for the installation
ABB's indoor instrument-transformer portfolio includes reference candidates such as TPU CTs and TJC, TJP or TDC VTs. These are research candidates, not a confirmed supply list. Instrument transformers have different functions and interfaces from power transformers and electronic sensors; similar terminology does not establish interchangeability.