rex615 prod intro en
Medium-voltage products

ABB Protection and Control Relays

Identify protection and control functions at feeder or substation level.

Explore the range

Overview

Start with the equipment to protect. A feeder, transformer or motor requires different protection functions and trip logic. Compare relay versions against the required inputs, outputs, communications and station architecture.

REX610 distribution protection

REX610 is a draw-out relay for basic distribution protection. Its modular current and voltage inputs let a panel builder configure the same relay platform for different feeders. Both IEC 61850 and Modbus are supported.

For a feeder that needs overcurrent and undervoltage protection, select the corresponding instrument inputs and configure the functions in ABB’s PCM600 engineering tool.

ABB REX610 technical manual
REX610 relay with its plug-in unit withdrawn from the case

Relion 615 series

The 615 series has dedicated models for different assets. REF615 protects and supervises overhead lines and cable feeders, RET615 protects transformers, and REM615 protects motors. The model letters identify which equipment the relay was designed to protect.

In a plant with both incoming feeders and motor bays, start a retrofit survey with the model and order code in each bay. These identify the application and installed I/O that the replacement needs to support.

Relion REF615 feeder relay with front display and operating keys

REX615 all-in-one protection and control

REX615 combines modular hardware with selectable protection packages. A scheme can use feeder, transformer, machine or grid-interconnection protection, with options for functions such as arc protection and voltage regulation.

When adding local generation to a distribution panel, compare the protection needed at the grid connection with the functions already assigned to the feeder. Select the application packages and I/O for both duties.

ABB Relion REX615
Two ABB REX615 protection relay housing sizes with front displays

REX640 modular protection and control

REX640 brings protection and control for primary distribution or generation into a modular relay. Its application packages extend from line differential and busbar protection to automatic generator synchronizing and on-load tap-changer voltage regulation.

At a generating plant, a breaker may close only when the generator is synchronized with the grid. REX640 can combine the synchronizing function with the generator’s protection in the same relay.

ABB Relion REX640
Two REX640 modular relay configurations with separate operator displays

SSC600 centralized substation protection

SSC600 is an industrial station computer with embedded protection and control software. Merging units at the switchgear digitize current and voltage. SSC600 receives these measurements over IEC 61850 and runs the protection for multiple bays in one place.

When a substation gains another feeder, its merging unit can feed the station-wide protection scheme. Plan the new bay’s measurements, network capacity and backup protection together.

ABB U.S. SSC600 product guide
Rack-mounted ABB SSC600 centralized protection and control device

SSC600 SW virtualized protection

SSC600 SW delivers the protection and control functions of SSC600 as a virtual machine. The software runs on a compatible industrial server and exchanges the same bay measurements and control signals with the switchgear.

For a substation that already hosts applications on virtual machines, check the server’s real-time performance, time synchronization and network capacity before allocating protection to that platform.

ABB centralized and virtualized protection
Operator viewing the substation single-line diagram for SSC600 SW on a laptop
ABB SSC600 SW centralized and virtualized protectionWatch on YouTube

ABB Ability Logic for distribution automation

ABB Ability Logic is automation software for substations and distribution networks. Engineers use Logic Workbench to build and simulate control sequences. The runtime collects field signals, calculates derived values and exchanges data with supervisory systems.

In a substation or microgrid, the same logic can check interlocks in a simulated switching sequence before commissioning and send equipment status to the control centre during operation.

ABB illustration locating substations, a control centre and battery storage on a distribution network
Specifications and selection

What to bring to a selection review

Identify the protected equipment, CT/VT inputs, protection functions, trip logic, binary I/O, communications and auxiliary supply. For a retrofit, include the installed device model, settings, software version and wiring interfaces.

Prepare the protection requirements

Identify the protected equipment, CT/VT inputs, protection functions, trip and control logic, binary I/O, communication protocols and auxiliary supply. For retrofit work, verify settings, versions and device interfaces.

Discuss the installation with Forte

For a Taiwan project, include the installation location, required delivery window and any existing panel information. Forte can review the enquiry and confirm the applicable models and scope for the project.

Discuss your project with Forte

Send your single-line diagram, model reference or project requirements.

Discuss relay applications and configuration