ABB Ring Main Units (RMU)
Connect ring feeders and transformer branches in secondary distribution.
Explore the rangeOverview
Plan the incoming feeders, transformer connection and protection for a secondary distribution ring. SafeRing provides ring main units and SafePlus offers compact switchgear with a choice of functional units. The insulation medium and ratings depend on the version.
SafeRing ring main units
SafeRing combines the ring cable switches and transformer feeder in a compact assembly. In the SF₆ version, a welded stainless-steel tank encloses the live switching parts and shields them from dust and humidity.
For a neighbourhood transformer station on a ring, two cable functions can connect the incoming and outgoing cables. The transformer branch can use a switch-fuse combination or a circuit breaker with a protection relay.

SafePlus compact switchgear
SafePlus is extendable secondary switchgear. Cable-switch and breaker modules can be combined into a lineup to match the site’s feeder plan. Transformer protection can be provided by fuses or by a relay-operated breaker.
At Finland’s Heinineva solar park, SafePlus switchgear and a Relion protection relay connect the transformer station serving the solar tracker field to the plant’s medium-voltage network.
ABB’s Heinineva solar park project
SafeRing Air ring main units
SafeRing Air uses dry air as its insulating gas. Its load-break switch uses a puffer mechanism to interrupt load current in dry air. ABB’s secondary distribution range includes Air configurations up to 24 kV.
For a compact utility substation replacing an SF₆ ring main unit, the Air range retains the familiar footprint and operating interface. Check the cable entry positions and the rating of each circuit against the existing installation.

SafePlus Air compact switchgear
SafePlus Air combines the configurable SafePlus lineup with a sealed dry-air tank. The available cable-switch and transformer-protection functions let a designer plan each connection on a secondary distribution network.
For its German distribution network, E.ON selected ABB’s 24 kV SafeRing Air and SafePlus Air equipment. Retaining familiar equipment dimensions and operating procedures was important for its existing compact substations.
ABB’s 24 kV network project with E.ON
What to bring to a selection review
List each incoming and outgoing circuit, the transformer protection scheme and any future extensions. Include the single-line diagram, site conditions, available space and required ratings. Specify any motor operation, remote monitoring or communications you need.
Define the functions before the version
Establish the number of incoming and outgoing circuits, transformer connection, protection method and expansion requirements. Verify SF₆ versions separately from dry-air versions such as SafeRing Air and SafePlus Air. Do not assume every product in the portfolio is SF₆-free.
Prepare an enquiry
Include the single-line diagram, circuit functions, ratings, available space, indoor or outdoor installation context and operating requirements. Specify remote operation or monitoring needs separately so the actual configuration can be checked rather than assumed to be standard.
Discuss the installation with Forte
For a Taiwan project, include the installation location, required delivery window and any existing panel information. Forte can review the enquiry and confirm the applicable models and scope for the project.