ABB Medium-Voltage Switchgear: GIS & AIS
Compare gas-insulated and air-insulated assemblies for primary and secondary distribution.
Compare GIS and AISOne assembly, several duties
Compare gas-insulated and air-insulated switchgear for primary distribution. The single-line arrangement, fault duty, available space and maintenance access help narrow the choice of panel and busbar system.
Two approaches to insulation
GIS · ZX2Gas-insulated switchgear
Live components are enclosed in gas-filled compartments. A compact arrangement can help where floor space is limited. Check the insulation medium and extension provisions for the specific design.
Explore ZX2 gas-insulated switchgear
AIS · UniGear ZS1Air-insulated switchgear
Air provides the main insulation between live parts. ABB’s UniGear family serves primary distribution; UniSec addresses secondary distribution. Review the panel configuration, cable entry and maintenance clearances.
Explore UniGear ZS1 air-insulated switchgearZX2 gas-insulated switchgear
ZX2 houses the circuit breaker and the busbars in separate, sealed gas compartments. Plug-in busbar connections join the panels into a single- or double-busbar lineup for primary distribution up to 40.5 kV.
At a utility substation or a data centre with two incoming supplies, compare the busbar arrangements against the required transfer scheme and the width available in the switchroom.
ABB ZX gas-insulated portfolio
ZX0.2 gas-insulated switchgear
ZX0.2 pairs a solid-insulated single busbar with a sealed gas compartment containing the circuit breaker and a three-position disconnector. The lineup can stand against a wall or on an open floor.
For a wind farm collector substation or an industrial feeder room with limited floor space, ZX0.2 offers a compact primary switchboard for systems up to 36 kV.

PrimeGear ZX0
PrimeGear ZX0 is a compact single-busbar panel for indoor substations. The solid-insulated busbar sits outside the sealed switching compartment. ABB offers dry-air insulation up to 12 kV and an SF₆ version up to 24 kV.
An airport or food-processing plant can place the panels along a wall to keep the centre of the switchroom clear. The site voltage and insulation specification determine which version is suitable.

UniGear ZS1 air-insulated switchgear
UniGear ZS1 uses a withdrawable VD4 vacuum circuit breaker in an air-insulated panel. Front access gives technicians room to withdraw the breaker for servicing. The range includes single-busbar, back-to-back double-busbar and double-level arrangements.
At the BorsodChem MCHZ chemical plant, ABB installed 123 UniGear ZS1 panels with Relion relays and AdvaSense sensors as part of a power-system upgrade carried out while production continued.
ABB UniGear portfolioABB’s BorsodChem switchgear project
AdvaSense indoor sensors
AdvaSense current sensors use a Rogowski coil around the conductor. Voltage sensors use a voltage divider. Their low-power outputs feed compatible protection relays and measurement devices in air- or gas-insulated switchgear.
A panel that needs both measurements can use a combined sensor in a single cast-resin body. Match the sensor output and connector to the relay input when specifying a new panel or upgrading an existing one.
ABB indoor sensors
EcoFlex prefabricated substations
EcoFlex packages the medium-voltage switchgear, transformer and low-voltage switchboard in one enclosure built to standard ISO transport dimensions. The complete substation can travel by road, rail or sea.
At a solar plant, the transformer can step the inverter output up to the collector-network voltage. At an industrial site the same substation concept can step the incoming medium voltage down for local loads.
ABB EcoFlex substation
What to bring to a selection review
Provide a single-line diagram, rated voltage and current, fault level, available space and installation conditions. Check internal-arc classification, service continuity and maintenance access for the exact assembly. For a secondary distribution ring, also review the ring main units.
Network and electrical duty
Provide the single-line diagram, system voltage, continuous current and specified short-circuit duty for each circuit.
Room layout and access
Include room dimensions, cable entry direction, operating and maintenance access, and any space reserved for future panels.
Project and service requirements
Identify the applicable standard, internal arc classification, service continuity requirements and environmental conditions. Match the final values to the selected panel documentation.
Discuss the installation with Forte
For a Taiwan project, include the installation location, required delivery window and any existing panel information. Forte can review the enquiry and confirm the applicable models and scope for the project.
Discuss your project with Forte